Presentations & Technical Papers
Presentations
Radiotherapy
RAMPS Presentation
EBT film based IMRT QA system
Snap shot of IMRT QA system solution
Diagnostic and Radiology
XR-R Product Presentation
CRCPD presentation

Media Files
SEC1
Intro click here to view click here to download
Validation protocol click here to view click here to download
Film handling click here to view click here to download
To download: right mouse click the download link and save to your computer
SEC2
Setting up the phantom click here to view click here to download
Projecting the plan click here to view click here to download
Calibrating the film click here to view click here to download
Digitizing the film click here to view click here to download
To download: right mouse click the download link and save to your computer
SEC3
Data Analysis click here to view click here to download
Final Demonstration click here to view click here to download
To download: right mouse click the download link and save to your computer

AAPM '07 Posters
A comparison between EDR2 and EBT for Helical Tomotherapy treatment dose verification: Avanzo M, Cappelletto C, Capra E, Dassie A, Drigo A, Ren Kaiser S, Sartor G
Application of GAFCHROMIC EBT for in-vivo dosimetry with Total body Irradiation (TBI) radiotherapy: F Su, C Shi, S Stathakis, N Papanikolaou

ESTRO '07 posters
Evaluation of an Epson flat bed scanner to read Gafchromic EBT films for radiation dosimetry: B. Ferreira, M. C. Lopes, M. Capela
Development of a QA procedure for IMRT plans using EBT radiochromic film: N. van Wieringen PhD, Y.R.J. van Herten, J.B. van de kamer PhD, A. Erogluer, A. Bel PhD, J. Wiersma PhD

Technical Papers
New development in scanning EBT film: Dr. David F. Lewis
Performance of the Vidar Red LED Dosimetry Pro Advantage™: A scanner optimized
for use with GAFCHROMIC EBT Dosimetry Film.
:
David F. Lewis
Pencil beam scanning at PTC-H: Martin Bues
Dose distribution measured by EBT for proton beam: M. Mumot, G. V. Mytsin, Y. I. Luchin
and A. G. Molokanov
Absorption spectroscopy of EBT model GAFCHROMIC™ film: Slobodan Devic, Nada Tomic,
Zhiyu Pang, Jan Seuntjens, Ervin B. Podgorsak, and Christopher G. Soares
Precise radiochromic film dosimetry using a flat-bed document scanner: Slobodan Devic, Jan Seuntjens, Edwin Sham, Ervin B. Podgorsak, C. Ross Schmidtlein, Assen S. Kirov, Christopher G. Soares
Accurate skin dose measurements using radiochromic film in clinical applications: S. Devic, J. Seuntjens, W. Abdel-Rahman, M. Evans, M. Olivares, E. B. Podgorsak, Té Vuong, Christopher G. Soares
Comparative skin dose measurement in the treatment of anal canal cancer: Conventional versus conformal therapy: Slobodan Devic, Gyorgy Hegyi, Té Vuong, Thierry Muanza, Ervin B. Podgorsak
Dosimetric properties of improved GAFCHROMIC films for seven different digitizers: Slobodan Devic, Jan Seuntjens, Gyorgy Hegyi, Ervin B. Podgorsak, Christopher G. Soares, Assen S. Kirov, Imad Ali, Jeffrey F. Williamson, Angel Elizondo
Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies: Sou-Tung Chiu-Tsao, Yunsil Ho, Ravi Shankar, Lin Wang, Louis B. Harrison
Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 Dosimetry PRO™: Ellen Wilcox, Ph.D., George Daskalov, Ph.D., Lucy Nedialkova, Ph.D.
Validation measurements of dose delivered from a novel electronic brachytherapy x-ray source: Steve Axelrod, Ph.D., Earl E. Dozier, Thomas W. Rusch, Ph.D.
Weak energy dependence of EBT GAFCHROMIC film dose response in the 50 kVp-10MVp X-ray range: Martin J Butson, Tsang Cheung, Peter K.N. Yu
Radiochromic Film Dosimetry: Azam Niroomand-Rad, Charles Robert Blackwell, Bert M. Coursey, Kenneth P. Gall, James M. Galvin, William L. McLaughlin, Ali S. Meigooni, Ravinder Nath, James E. Rodgers, Christopher G. Soares
Evaluation of GAFCHROMIC EBT prototype B for external beam dose verification: M. Todorovic, M. Fischer, F. Cremers, E. Thom, R. Schmidt
Evaluation of GAFCHROMIC EBT Film for IMRT QA Using Two Different Scanners: S. Trichter, F. Trichter, A. Sabbas, D. Lovelock, F. Kulidzhanov
CORVUS IMRT Film Dosimetry Using Novel GAFCHROMIC EBT Film: F. Trichter, S. Trichter
Evaluation of a practical and low cost GAFCHROMIC film/flat-bed scanner combination for planar dosimetry: Goss M, Guo P, Yin FF, Oldham M
Multidimensional Dosimetry Without Film Processors: D Low, J Dempsey, P Jursinic, M Oldham
Radiochromic film dosimetry for Ir-192 HDR source: Determination of TG43 parameters: Sou-Tung Chiu-Tsao
Two dimensional CT dosimetry using new GAFCHROMIC XR-QA radiochromic film: Slobodan Devic and Nagi Sharoubim
Copyright © 2008 International Specialty Products. All Rights Reserved.